Product Features
Stable life cycle, guaranteed 12, 000, 0000 times
Different surface treatment.. BSPP,BSPT,NPT thread are available
Manifolds are available for all types and size


How to Order?
4A —————————— 1 —————————— 10 —————————— 06 ——————————
| | | |
| | | |
| Series Code | Port Size
| 100 Series Coil and Type M5: 10-32UNF
| 200 Series 10: Single-head 06:NPT1/8”
| 300 Series Double-position 08:NPT1/4”
| 400 Series 20: Double-head 10:NPT3/8”
Specification Code Double-position 15:NPT1/2”
4A:Two-position Three-way 30C: Double air control *BSP,PT,NPT thread
Pneumatic Control Valve 3/5way closed center are available
30E: Double air control
3/5way exhaust center
30P: Double air control
3/5way Pressure center
Specifications
| Model | 4A110-06 | 4A120-06 | 4A130-06 | 4A210-08 | 4A220-08 | 4A230C-08 | 4A310-10 | 4A320-10 | 4A330C-10 | 4A410-10 | 4A420-10 | 4A430C-10 |
| Working Medium | 40micron Filtered Air | |||||||||||
| Operating | External Control | |||||||||||
|
Port Size |
Air Inlet = Air OutletExhaust = NPT1 / 8″ | Air Inlet = Air Outlet = NPT1 / 4″
Exhaust = NPT1 / 8″ |
Air Inlet = Air Outlet = NPT3 / 8″
Exhaust = NPT1 / 4″ |
Air Inlet = Air Outlet =Exhaust = NPT1/2″ | ||||||||
| Effective Section Area | 12mm²
CV = 0 . 67 |
9mm²
CV = 0 . 50 |
16mm²
CV = 0 . 89 |
12mm²
CV = 0 . 67 |
30mm²
CV = 1 . 67 |
18mm²
CV = 1.00 |
50mm²
CV = 2.79 |
30mm²
CV = 1.68 |
||||
| Working-pressure | 0.15-0.8Mpa | |||||||||||
| Max Test PressureAmbient | 1.2Mpa | |||||||||||
| Ambient-temperature | -5–60℃ | |||||||||||
| Switching Frequency | 5cycle / Sec | 3cycle / Sec | 5cycle / Sec | 3cycle / Sec | 4cycle / Sec | 3cycle / Sec | ||||||